Please
Watch Demo Video
|
Output charts, graphs, spreadsheets or
email your results anywhere in the world
Internal Temp Sensor Range
-40°F to 150°F (-40°C to 66°C)
External Temp Sensor Range
-40°F to 302°F (-40°C to 150°C)
External Low-Temp Sensor Range -112°F to 230°F (-80°C to 110°C)
Temperature Accuracy ±1°F (0.5°C) at -32°F to 150°F (0°C to 66°C)
±2°F (1°C) over entire range
Humidity Accuracy ±5% between 20% to 90% RH
Operating Humidity Range 1% to 99% RH
Temperature Resolution 0.1°F/C
Logged Data Capacity 7,900 to 10,000 data points
Programmable Alarm Levels High and Low Levels over entire range
Startup Alarm Delay Skip 1 to 16 points
Operating Alarm Delay 0 to 79 minute delay filter
Logging Time Interval Range 3 seconds to 24 hours
Programmable Delayed Start 0 seconds to 256 days
LED Indicators 12-second flashing red for alarm; green for active
Battery Type CR2450 3v lithium; user replaceable; 1-year life
Dimensions/ Enclosure ABS plastic case, 3.25 x 2.25 x .75 in. (8.3
x 5.7 x1.9 cm.)
Water Resistance Withstands immersion up to six inches
Shock Resistance Withstands3-foot drop to hard surface
Certification T.U.V.- CE Mark
Software Requirements FlashLink Program Manager Software #20210
|