HOW
TO USE THE WARMMARK TIME-TEMPERATURE TAG
The
WarmMark Tag is shelf stable and can be stored at room temperature prior
to
application.
Prior
to use, the WarmMark Tag must be pre-conditioned for a minimum of 30
minutes
at least 5 C below the response temperature noted on the label of the
Tag. The purpose of this pre-conditioning is to insure that the chemical
inside the Tag is in a complete solid state at the time the Activator
Tab is pulled. If any of the chemical is still in a liquid state when
the Tab is pulled, the chemical will start migrating down the track of
the Tag and will not stop until a complete solid state is reached.
Apply
the WarmMark Tag by peeling the release liner off the back and adhering
the pressure sensitive adhesive backing to a clean, dry surface.
Fold
the Activator Tab up and then pull the Tab out of the WarmMark Tag along
with the attached strip of film. This will allow the pad saturated with
chemical to come in direct contact with the blotter paper track running
under each of the three windows of the Tag.
Once
the WarmMark Tag has been activated by pulling out the Tab, the Tag
should be returned to a temperature below its response temperature as
soon as practically possibly. This will insure that the chemical inside
the Tag remains in a solid state.
|